redlight.store

🐀 Rat · 2017 · Taiwan (Kaohsiung)

The Antinociceptive Effect of Light-Emitting Diode Irradiation on Incised Wounds Is Correlated with Changes in Cyclooxygenase 2 Activity, Prostaglandin E2, and Proinflammatory Cytokines.

Chia · Pain Res Manag · 2017

The protocol this study used

Wavelength
940 nm
Dose
4 J/cm²
Sessions
—
Per session
30 min

What the authors concluded

LED therapy attenuated the decrease in thermal withdrawal latency in all the irradiated groups and the decrease in the mechanical withdrawal threshold in the L-I group only. The expression levels of COX-2, PGE2, and IL-6 were significantly decreased in the three LED-treated groups, whereas IL-1β and TNF-α were significantly decreased only in the L-I group compared with their levels in the I group

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 4 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 81 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 1 min 38 sec / session
at 40.7 mW/cm²
BestQool Pro300
630 · 660 · 850 · 940 nm
Brand claim
$899
≈ 38 sec / session
at 106 mW/cm²
MitoADAPT MID 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Brand claim
$999
≈ 69 sec / session
at 58 mW/cm²
TheraLight 360
633 · 810 · 850 · 940 nm
Brand claim
Check price
≈ 24 sec / session
at 165 mW/cm²
BestQool Pro100
630 · 660 · 850 · 940 nm
Not published
$319
no irradiance published

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 28469528 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.