🧑 Human 📄 Case report ⌛ 13 weeks · 2014 · Canada (Quebec)

Pulsed versus continuous wave low-level light therapy on osteoarticular signs and symptoms in limited scleroderma (CREST syndrome): a case report.

Barolet D · J Biomed Opt · 2014

The protocol this study used

Wavelength
940 nm
Dose
81 J/cm²
Sessions
2
Per session
30 min

What the authors concluded

The patient was treated two to three times a week for 13 weeks using a sequential pulsing mode on one elbow and a CW mode on the other. Efficacy assessments included inflammation, symptoms, pain, health scales, patient satisfaction, clinical global impression, and adverse effects monitoring. Considerable functional and morphologic improvements were observed after LLLT, with the best results seen

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 81 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 27 min 20 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 33 min 10 sec / session
at 40.7 mW/cm²
BestQool Pro300
630 · 660 · 850 · 940 nm
Brand claim
$899
≈ 12 min 44 sec / session
at 106 mW/cm²
MitoADAPT MID 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Brand claim
$999
≈ 23 min 17 sec / session
at 58 mW/cm²
TheraLight 360
633 · 810 · 850 · 940 nm
Brand claim
Check price
≈ 8 min 11 sec / session
at 165 mW/cm²
BestQool Pro100
630 · 660 · 850 · 940 nm
Not published
$319
no irradiance published

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 25393970 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.