redlight.store

🧑 Human 🎲 Randomized trial, double-blind 👥 22 participants ⌛ 5-day treatment -> 3-day follow-up (?) · 2024 · Iran (Urmia)

Efficacy of adjuvant Photobiomodulation therapy in recurrent herpes labialis, a randomized clinical trial study

Seyyedi · Photodiagnosis Photodyn Ther · 2024

The protocol this study used

Wavelength
940 nm
Dose
4 J/cm²
Sessions
—
Per session
—

What the authors concluded

Pain intensity in PBM + Acyclovir group was significantly lower than Acyclovir without PBM group in both two and three days after intervention (p < 0.001). The lesion size in case group was significantly lower on 7 and 10 days (p <0.05). Patients in the treatment group were significantly more satisfied with their treatment process (p=0.008)." "PBMT can be used as an adjuvant tool to acyclovir cr

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 4 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 81 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 1 min 38 sec / session
at 40.7 mW/cm²
BestQool Pro300
630 · 660 · 850 · 940 nm
Brand claim
$899
≈ 38 sec / session
at 106 mW/cm²
MitoADAPT MID 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Brand claim
$999
≈ 69 sec / session
at 58 mW/cm²
TheraLight 360
633 · 810 · 850 · 940 nm
Brand claim
Check price
≈ 24 sec / session
at 165 mW/cm²
BestQool Pro100
630 · 660 · 850 · 940 nm
Not published
$319
no irradiance published

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 39009206 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.