🧑 Human ⚔ Comparison study, self-controlled 👥 7 participants ⌛ 12-week treatment -> 12-week follow-up · 2021 · China (Shanghai)

Treatment of androgenetic alopecia with 5-aminolevulinic acid photodynamic therapy: A randomized, placebo-controlled, split-scalp study of efficacy and safety

Cao · Photodiagnosis Photodyn Ther · 2021

The protocol this study used

Wavelength
630 nm
Dose
60 J/cm²
Sessions
6
Per session
—

What the authors concluded

It is needed to be mentioned that the red light treated side also showed a decreased tendency in hair density at 1 week and 12 weeks after the last treatment, which seems to be different from other studies about red light therapy. Recently, low-level light therapy (LLLT) has been applied to promote hair regrowth in AGA patients by its photobiomodulatory effect [17–19]. In those studies, the wave

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 60 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 13 min 4 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 18 min 41 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 11 min 4 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 20 min 15 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 24 min 34 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 14 min 17 sec / session
at 70 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 34418549 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.