🧑 Human 🎲 Randomized trial, sham-controlled 👥 51 participants ⌛ one session -> 2wk follow-up · 2016 · USA (Austin, TX)

Transcranial Laser Stimulation as Neuroenhancement for Attention Bias Modification in Adults with Elevated Depression Symptoms.

Disner · Brain Stimul · 2016

The protocol this study used

Wavelength
1064 nm
Dose
60 J/cm²
Sessions
1
Per session
8 min

What the authors concluded

A significant three-way interaction between LLLT condition, ABM response, and time indicated that right LLLT led to greater symptom improvement among participants whose attention was responsive to ABM (i.e., attention was directed away from negative stimuli). Minimal change in depression was observed in the left and sham LLLT." "The results suggest that larger clinical trials examining the effic

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 60 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 11 min 4 sec / session
at 90.3 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 14 min 17 sec / session
at 70 mW/cm²
Rouge Pro G4
630 · 650 · 660 · 670 · 810 · 830 · 850 · 1060 nm
Measured
$1,121
≈ 16 min 54 sec / session
at 59.2 mW/cm²
PlatinumLED BIOMAX PRO ULTRA
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,599
≈ 9 min 54 sec / session
at 101 mW/cm²
Block Blue Light ULTIMATE XXL
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Measured
$4499.95
≈ 13 min 20 sec / session
at 75 mW/cm²
Block Blue Light PowerPanel MAX
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Brand claim
$1099.95
≈ 12 min 12 sec / session
at 82 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 27267860 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.