redlight.store

🧑 Human 🎲Randomized trial, sham-controlled, crossover 👥 5 participants ⌛ 5-week treatment / 4-week washout period / 15-17 week study · 2021 · USA (Austin, TX)

Transcranial Infrared Laser Stimulation Improves Cognition in Older Bipolar Patients: Proof of Concept Study

O'Donnell · J Geriatr Psychiatry Neurol · 2021

The protocol this study used

Wavelength
1064 nm
Dose
75 J/cm²
Sessions
5
Per session
10 min

What the authors concluded

We found TILS-induced improvements in cognitive performance on the tasks that measure cognitive flexibility and impulsivity, after 5 weekly sessions of TILS. We concluded that TILS appeared both safe and effective in helping alleviate the accelerated cognitive decline present in older bipolar patients." Comment: The authors incorrectly sum the fluence across separate irradiation points.

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 75 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 13 min 51 sec / session
at 90.3 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 17 min 51 sec / session
at 70 mW/cm²
Rouge Pro G4
630 · 650 · 660 · 670 · 810 · 830 · 850 · 1060 nm
Measured
$1,121
≈ 21 min 7 sec / session
at 59.2 mW/cm²
PlatinumLED BIOMAX PRO ULTRA
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,599
≈ 12 min 23 sec / session
at 101 mW/cm²
Block Blue Light ULTIMATE XXL
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Measured
$4499.95
≈ 16 min 40 sec / session
at 75 mW/cm²
Block Blue Light PowerPanel MAX
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Brand claim
$1099.95
≈ 15 min 15 sec / session
at 82 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 33525934 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.