🐀 Rat · 2016 · Iran (Tehran)

The effects of photobiomodulation therapy on Staphylococcus aureus infected surgical wounds in diabetic rats. A microbiological, histopathological, and biomechanical study.

Ranjbar & Takhtfooladi · Acta Cir Bras · 2016

The protocol this study used

Wavelength
685 nm
Dose
3 J/cm²
Sessions
5
Per session
—

What the authors concluded

The result revealed that PBMT resulted in a significant decrease in S. aureus CFU in the PBMT group in comparison to the control group (P<0.05). The length of wounds, in the 2nd and 3rd weeks, in the PBMT group were significantly shorter compared to the control group (P<0.05). PBMT caused a significant increase in the histological parameters in comparison to the control group (P<0.05). Moreover,

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 3 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 61 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 74 sec / session
at 40.7 mW/cm²
Rouge Pro G4
630 · 650 · 660 · 670 · 810 · 830 · 850 · 1060 nm
Measured
$1,121
≈ 51 sec / session
at 59.2 mW/cm²
Theradome PRO LH80
680 nm
Brand claim
$845.99
no irradiance published
EMR-TEK Firewave
630 · 670 · 830 nm
Brand claim
$312.49
≈ 22 sec / session
at 138.39 mW/cm²
MitoADAPT MID 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Brand claim
$999
≈ 52 sec / session
at 58 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 27579876 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.