🧑 Human 🎲 Randomized trial, double-blind 👥 35 participants, 27 completed ⌛ 4-week treatment -> 2-month follow-up · 2009 · Hungary (Orosháza-Gyopáros)

The effect of low-level laser in knee osteoarthritis: a double-blind, randomized, placebo-controlled trial.

Hegedus · Photomed Laser Surg · 2009

The protocol this study used

Wavelength
830 nm
Dose
48 J/cm²
Sessions
8
Per session
—

What the authors concluded

In the group treated with active LLLT, a significant improvement was found in pain (before treatment [BT]: 5.75; 2 mo after treatment : 1.18); circumference (BT: 40.45; AT: 39.86); pressure sensitivity (BT: 2.33; AT: 0.77); and flexion (BT: 105.83; AT: 122.94). In the placebo group, changes in joint flexion and pain were not significant. Thermographic measurements showed at least a 0.5 degrees C

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 48 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 10 min 27 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 14 min 57 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 8 min 52 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 16 min 12 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 19 min 39 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 11 min 26 sec / session
at 70 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 19530911 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.