🧑 Human 🎲 Randomized trial, double-blind 👥 35 participants ⌛ 4 weeks · 2013 · Korea (Seoul)

The clinical and histological effect of home-use, combination blue-red LED phototherapy for mild-to-moderate acne vulgaris in Korean patients: a double-blind, randomized controlled trial.

Kwon · Br J Dermatol · 2013

The protocol this study used

Wavelength
420, 660 nm
Dose
0.91 J/cm²
Sessions
4
Per session
2 min 30 sec

What the authors concluded

At the final visit at 12 weeks, both inflammatory and noninflammatory acne lesions had decreased significantly, by 77% and 54%, respectively, in the treatment group. No significant difference was observed in the control group. In the treatment group, sebum output reduction, attenuated inflammatory cell infiltrations and a decreased size of the sebaceous gland were found. The immunostaining inte

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 0.91 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 12 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 17 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 10 sec / session
at 90.3 mW/cm²
HoogaHealth PRO1500
660 · 850 nm
Measured
$1,199
≈ 11 sec / session
at 86 mW/cm²
Joovv Solo 3.0
660 · 850 nm
Measured
$1,499
≈ 15 sec / session
at 59.2 mW/cm²
LUMEBOX 2.0
660 · 850 nm
Measured
$629
≈ 7 sec / session
at 125 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 23278295 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.