redlight.store

🐀 Rat · 2011 · China (Shanghai)

The 800-nm diode laser irradiation induces skin collagen synthesis by stimulating TGF-β/Smad signaling pathway.

Dang · Lasers Med Sci · 2011

The protocol this study used

Wavelength
800 nm
Dose
20 J/cm²
Sessions
4
Per session
—

What the authors concluded

The 800-nm diode laser treatments markedly improved the histological structure and increased dermal thickness compared to the non-irradiated controls. Laser irradiation at 40 J/cm(2) significantly up-regulated the expression of procollagen type I and IV, TGF-β and Smad2, 3, 4. The p-Smad2 and p-Smad3 levels were also enhanced in the laser-irradiated skin. The 800-nm laser is effective in improv

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 20 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 6 min 14 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 3 min 41 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 6 min 45 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 8 min 11 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 4 min 46 sec / session
at 70 mW/cm²
Infraredi Pro Max 2.0
630 · 660 · 810 · 830 · 850 nm
Measured
$959
≈ 4 min 38 sec / session
at 72 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 21892789 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.