🧑 Human 🎲 Randomized trial, sham-controlled 👥 42 participants ⌛ 4-5 weeks · 2022 · Thailand (Bangkok)

Short-Term Efficacy of High-Intensity Laser Therapy in Alleviating Pain in Patients with Knee Osteoarthritis: A Single-Blind Randomised Controlled Trial

Siriratna · Pain Res Manag · 2022

The protocol this study used

Wavelength
808, 905 nm
Dose
22.39 J/cm²
Sessions
10
Per session
8 min

What the authors concluded

At the end of the study, the overall analysis showed a significant decrease in VAS and T-WOMAC scores in both the groups; a greater decrease in scores was found in the HILT group than in the control group (p < 0.001). The between-group comparison also showed a significant difference in VAS, but not in the T-WOMAC score, favouring HILT (p < 0.05)." Comment: Only modest differences between the gro

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 22.39 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 6 min 59 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 4 min 8 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 7 min 33 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 9 min 10 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 5 min 20 sec / session
at 70 mW/cm²
Infraredi Pro Max 2.0
630 · 660 · 810 · 830 · 850 nm
Measured
$959
≈ 5 min 11 sec / session
at 72 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 36313402 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.