redlight.store

🧑 Human ⚔ Comparison study, randomized 👥 30 participants ⌛ 3 weeks · 2011 · Italy (Foggia)

Short-term effects of high-intensity laser therapy versus ultrasound therapy in the treatment of low back pain: a randomized controlled trial.

Fiore · Eur J Phys Rehabil Med · 2011

The protocol this study used

Wavelength
1064 nm
Dose
0.76 J/cm²
Sessions
15
Per session
10 min

What the authors concluded

At the end of the 3-week intervention, participants in the HILT group showed a significantly greater decrease in pain (measured by the VAS) and an improvement of related disability (measured by the OLBPDQ) compared with the group treated with US therapy.

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 0.76 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 8 sec / session
at 90.3 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 11 sec / session
at 70 mW/cm²
Rouge Pro G4
630 · 650 · 660 · 670 · 810 · 830 · 850 · 1060 nm
Measured
$1,121
≈ 13 sec / session
at 59.2 mW/cm²
PlatinumLED BIOMAX PRO ULTRA
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,599
≈ 8 sec / session
at 101 mW/cm²
Block Blue Light ULTIMATE XXL
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Measured
$4499.95
≈ 10 sec / session
at 75 mW/cm²
Block Blue Light PowerPanel MAX
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Brand claim
$1099.95
≈ 9 sec / session
at 82 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 21654616 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.