🧑 Human ⚔ Comparison trial, randomized, double-blind 👥 60 participants ⌛ 8 weeks · 2018 · Slovenia (Ljubljana)

Phototherapy with LED Shows Promising Results in Healing Chronic Wounds in Diabetes Mellitus Patients: A Prospective Randomized Double-Blind Study.

Frangež · Photomed Laser Surg · 2018

The protocol this study used

Wavelength
580, 625, 660, 850, 900 nm
Dose
0.576 J/cm²
Sessions
24
Per session
5 min

What the authors concluded

After 8 weeks, the mean surface in the LED group was 56% of the baseline surface and 65% in the Co-group (p > 0.05). Falanga score evaluation showed significantly faster wound bed healing in the LED group compared with the Co-group (p < 0.05)." Comment: There was only 3.3x total energy difference between PBM and the so-called "control group". It could explain the small difference between the g

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 0.576 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 8 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 11 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 6 sec / session
at 90.3 mW/cm²
HoogaHealth PRO1500
660 · 850 nm
Measured
$1,199
≈ 7 sec / session
at 86 mW/cm²
Joovv Solo 3.0
660 · 850 nm
Measured
$1,499
≈ 10 sec / session
at 59.2 mW/cm²
LUMEBOX 2.0
660 · 850 nm
Measured
$629
≈ 5 sec / session
at 125 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 29668397 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.