redlight.store

🧪 In vitro + ex vivo human skin · 2024 · China (Shanghai)

Photobiomodulation Using 830 nm Lighting-Emitting Diode Inhibits Melanogenesis via FOXO3a in Human Melanocyte

Dan · Pigment Cell Melanoma Res · 2024

The protocol this study used

Wavelength
830 nm
Dose
5 J/cm²
Sessions
—
Per session
—

What the authors concluded

Our results showed that 830 nm LED at fluences ranging from 5 to 20 J/cm2 inhibited melanosome maturation and reduced melanin content, tyrosinase activity and melanogenesis-related proteins. 830 nm LED inhibited the phosphorylation of AKT and its downstream FOXO3a, leading to nuclear translocation of FOXO3a. Furthermore, FOXO3a knockdown and AKT activator like SC79 could reverse the melanogenesis

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 5 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 65 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 1 min 33 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 55 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 1 min 41 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 2 min 3 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 71 sec / session
at 70 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 39169669 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.