🧑 Human 🎲 Randomized trial, self-controlled 👥 9 participants ⌛ until epithelization (8 days in treatment group, 16 days in control group) · 2024 · Israel (Jerusalem)

Photobiomodulation Treatment for Second-Degree Burn Treatment-A Double-Blinded Controlled Pilot Trial

Adler · Photobiomodul Photomed Laser Surg · 2024

The protocol this study used

Wavelength
660, 840 nm
Dose
2.4 J/cm²
Sessions
3
Per session
—

What the authors concluded

Patients received three to five treatments with a mean epithelization time of 16 days (±2.89 standard deviation [SD]) in the control area, while only 7.56 (±2.29 SD) in the treatment area. The mean percent reduction in healing time was 46.22% (±4.24 SD), which was found to be statistically significant (p = 0.004).

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 2.4 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 31 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 45 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 27 sec / session
at 90.3 mW/cm²
HoogaHealth PRO1500
660 · 850 nm
Measured
$1,199
≈ 28 sec / session
at 86 mW/cm²
Joovv Solo 3.0
660 · 850 nm
Measured
$1,499
≈ 41 sec / session
at 59.2 mW/cm²
LUMEBOX 2.0
660 · 850 nm
Measured
$629
≈ 19 sec / session
at 125 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 39724004 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.