redlight.store

🧑 Human 🎲 Randomized trial, double-blind, crossover 👥 13 participants ⌛ 2 sessions (1 active, 1 sham) with 7-day washout -> 72h follow-up after session · 2021 · Brazil (Londrina)

Photobiomodulation Therapy at 808 nm Does Not Improve Biceps Brachii Performance to Exhaustion and Delayed-Onset Muscle Soreness in Young Adult Women: A Randomized, Controlled, Crossover Trial

Azuma · Front Physiol · 2021

The protocol this study used

Wavelength
808 nm
Dose
250 J/cm²
Sessions
1
Per session
70 sec

What the authors concluded

There was a significant (time, p < 0.05) reduction in the number of repetitions performed and an increase in RPE over six sets, with no statistical differences between placebo and active laser conditions (treatment × time, p > 0.05).

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 250 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 77 min 53 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 46 min 9 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 84 min 21 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 102 min 23 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 59 min 31 sec / session
at 70 mW/cm²
Infraredi Pro Max 2.0
630 · 660 · 810 · 830 · 850 nm
Measured
$959
≈ 57 min 52 sec / session
at 72 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.