redlight.store

🧪 In vitro · 2026 · UK (Oxford)

Photobiomodulation restores blood-brain barrier integrity after hypoxia via endothelial von Willebrand factor modulation in a humanised tricellular transwell model

Domocos · J Physiol · 2026

The protocol this study used

Wavelength
635, 810, 904, 1064 nm
Dose
33.5 J/cm²
Sessions
3
Per session
5 min

What the authors concluded

Hypoxia significantly reduced transendothelial electrical resistance (TEER), whereas PBM restored barrier function in endothelial monocultures and tri-cultures. Endothelial cells exhibited the most pronounced hypoxic response, characterised by increased expression of hypoxia-inducible factor-1α (HIF-1α), plasminogen activator inhibitor-1 and von Willebrand factor (vWF), all attenuated by PBM.

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 33.5 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 7 min 18 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 10 min 26 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 6 min 11 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 11 min 18 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 13 min 43 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 7 min 59 sec / session
at 70 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.