🧑 Human 🎲 Randomized trial, double-blind 👥 26 participants (46 knees) ⌛ 4-week treatment -> 3-month follow-up · 2021 · Israel (Jerusalem)

Photobiomodulation as an Adjunctive Treatment to Physiotherapy for Reduction of Anterior Knee Pain in Combat Soldiers: A Prospective, Double-Blind, Randomized, Pragmatic, Sham-Controlled Trial

Gavish · Lasers Surg Med · 2021

The protocol this study used

Wavelength
660, 810, 850 nm
Dose
3 J/cm²
Sessions
8
Per session
60 sec

What the authors concluded

Post-treatment pain was significantly reduced in the PT+PBM group, compared with baseline and sham (Δpain, VAS, mean ± SD: PT + PBM = -19 ± 23, P = 0.002; PT + Sham = -6 ± 21, P = 0.16; between groups, P = 0.032). At 3-month follow-up, pain reduction was similar between groups; however, the Kujala score was significantly improved only in the PBM-treated group (ΔKujala: PT + PBM = 11 ± 10, P = 0.0

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 3 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 39 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 56 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 33 sec / session
at 90.3 mW/cm²
HoogaHealth PRO1500
660 · 850 nm
Measured
$1,199
≈ 35 sec / session
at 86 mW/cm²
Joovv Solo 3.0
660 · 850 nm
Measured
$1,499
≈ 51 sec / session
at 59.2 mW/cm²
LUMEBOX 2.0
660 · 850 nm
Measured
$629
≈ 24 sec / session
at 125 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.