redlight.store

🧑 Human 📄 Single-arm trial 👥 15 participants ⌛ 4-week treatment / 3-month study · 2008 · Italy (Brescia)

Non-invasive diagnostic evaluation of phototherapeutic effects of red light phototherapy of acne vulgaris.

Zane · Photodermatol Photoimmunol Photomed · 2008

The protocol this study used

Wavelength
600, 750 nm
Dose
20 J/cm²
Sessions
8
Per session
—

What the authors concluded

A significant improvement of acne lesions and a significant decrease of skin sebum excretion and TEWL of the face were registered at the end of the therapy and at the 3-month follow-up visit. The results could be related to a reduced follicular colonization of Propionibacterium acnes, in that it was lethally damaged by photoactivated endogenous porphyrins.

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 20 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 6 min 14 sec / session
at 53.5 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 6 min 45 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 8 min 11 sec / session
at 40.7 mW/cm²
MitoPRO 300X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$449
≈ 6 min 26 sec / session
at 51.8 mW/cm²
Block Blue Light ULTIMATE XXL
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Measured
$4499.95
≈ 4 min 27 sec / session
at 75 mW/cm²
Block Blue Light PowerPanel MAX
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Brand claim
$1099.95
≈ 4 min 4 sec / session
at 82 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 18811865 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.