🧑 Human 🎲 Randomized trial, sham-controlled 👥 46 participants ⌛ 8 weeks of treatment -> 8-week follow-up · 2016 · Brazil (Santos)

Non-ablative radiofrequency associated or not with Low Level Laser Therapy on the treatment of facial wrinkles in adult women: a randomized single-blind clinical trial.

Pereira · J Cosmet Laser Ther · 2016

The protocol this study used

Wavelength
658 nm
Dose
3.82 J/cm²
Sessions
24
Per session
—

What the authors concluded

LLLT did not potentiate RF treatment." "The present findings did not show significant differences on classification of nasolabial folds and periorbital wrinkles through scales after treatment. However, aesthetic improvement was observed in nasolabial folds on the right side of face for both treatment groups (RG and RLG) and participants’ subjective perception." "It is supposed that aesthetic im

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 3.82 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 50 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 71 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 42 sec / session
at 90.3 mW/cm²
HoogaHealth PRO1500
660 · 850 nm
Measured
$1,199
≈ 44 sec / session
at 86 mW/cm²
Joovv Solo 3.0
660 · 850 nm
Measured
$1,499
≈ 65 sec / session
at 59.2 mW/cm²
LUMEBOX 2.0
660 · 850 nm
Measured
$629
≈ 31 sec / session
at 125 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 42696342 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.