Low-level laser treatment stimulates hair growth via upregulating Wnt10b and β-catenin expression in C3H/HeJ mice.

Zhang · Lasers Med Sci

The protocol this study used

Wavelength
635, 655 nm
Dose
1 J/cm²
Sessions
10
Per session
—

What the authors concluded

Hair follicle number in both groups showed no difference; however, the hair follicle length presented a significant difference. Wnt10b protein was detected on the second day in hair matrix cells in the LLLT group but not in the control group. PCR and western blot results both illustrated that expression of Wnt10b and β-catenin was significantly higher in the LLLT group than in the control group.

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 1 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 13 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 19 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 11 sec / session
at 90.3 mW/cm²
HoogaHealth PRO1500
660 · 850 nm
Measured
$1,199
≈ 12 sec / session
at 86 mW/cm²
Joovv Solo 3.0
660 · 850 nm
Measured
$1,499
≈ 17 sec / session
at 59.2 mW/cm²
LUMEBOX 2.0
660 · 850 nm
Measured
$629
≈ 8 sec / session
at 125 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 28508243 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.