🧑 Human 🎲 Randomized trial, double-blind 👥 22 participants ⌛ 8 weeks · 2018 · Brazil (Natal)

Low-level laser therapy combined to functional exercise on treatment of fibromyalgia: a double-blind randomized clinical trial.

Germano Maciel · Lasers Med Sci · 2018

The protocol this study used

Wavelength
808 nm
Dose
142.85 J/cm²
Sessions
24
Per session
11 min 20 sec

What the authors concluded

A reduction in pain and improvement in functional and muscular performance, depression, and quality of life were observed in both groups (p < 0.05); however, with no significant differences between them (p > 0.05). In conclusion, the benefic effects of functional exercise were not improved by combination with LLLT." Comment: Some improvements seemed larger in laser group, without statistical sig

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 142.85 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 44 min 30 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 26 min 22 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 48 min 12 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 58 min 30 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 34 min 1 sec / session
at 70 mW/cm²
Infraredi Pro Max 2.0
630 · 660 · 810 · 830 · 850 nm
Measured
$959
≈ 33 min 4 sec / session
at 72 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 29931588 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.