🧑 Human 🎲 Randomized trial, double-blind 👥 17 participants ⌛ single session -> 4-day follow-up · 2014 · Brazil (Jequie)

Light-emitting diode phototherapy improves muscle recovery after a damaging exercise.

Borges · Lasers Med Sci · 2014

The protocol this study used

Wavelength
630 nm
Dose
20.4 J/cm²
Sessions
1
Per session
2 min

What the authors concluded

Our results showed that the muscle soreness, muscle strength loss, and ROM impairments were significantly reduced up to 96 h after a damaging eccentric exercise bout for the LEDT group compared with the PLACEBO group. A single LEDT (630 nm) intervention immediately after a damaging eccentric exercise bout was effective in terms of attenuating the muscle soreness and muscle strength loss and ROM

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 20.4 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 4 min 27 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 6 min 21 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 3 min 46 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 6 min 53 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 8 min 21 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 4 min 51 sec / session
at 70 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 24258312 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.