redlight.store

🧪 In vitro · 2018 · China (Shanghai)

Light-emitting diode 585nm photomodulation inhibiting melanin synthesis and inducing autophagy in human melanocytes.

Chen · J Dermatol Sci · 2018

The protocol this study used

Wavelength
585 nm
Dose
5 J/cm²
Sessions
—
Per session
—

What the authors concluded

Our finding demonstrated that LED photomodulation with 585nm wavelength suppressed melanin content in [human epidermal melanocyte]s, and the effect was caused by its dose-dependent inhibition on melanogenesis and the induction of [human epidermal melanocyte]s autophagy. This may provide new insights into the efficacy of LED photomodulation in the treatment of hyperpigmentation disorders.

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 5 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 1 min 33 sec / session
at 53.5 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 1 min 41 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 2 min 3 sec / session
at 40.7 mW/cm²
MitoPRO 300X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$449
≈ 1 min 37 sec / session
at 51.8 mW/cm²
Block Blue Light ULTIMATE XXL
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Measured
$4499.95
≈ 67 sec / session
at 75 mW/cm²
Block Blue Light PowerPanel MAX
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Brand claim
$1099.95
≈ 61 sec / session
at 82 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 29065997 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.