redlight.store

🧪 In vitro · 2022 · Korea (Sejong)

Irradiation with 590-nm yellow light-emitting diode light attenuates oxidative stress and modulates UVB induced change of dermal fibroblasts

Hong · Exp Dermatol · 2022

The protocol this study used

Wavelength
590 nm
Dose
34.2 J/cm²
Sessions
—
Per session
15 min

What the authors concluded

LED irradiation significantly attenuated UVB-induced reactive oxygen species generation and UVB-induced phosphorylation of JNK, c-Fos, and c-Jun. In addition, the procollagen levels were recovered significantly, and MMP-9 levels were significantly suppressed after LED irradiation. The UVB-induced phosphorylation levels of NF-κB and pro-inflammatory enzyme COX-2 also significantly decreased.

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 34.2 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 10 min 39 sec / session
at 53.5 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 11 min 32 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 14 min / session
at 40.7 mW/cm²
MitoPRO 300X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$449
≈ 11 min / session
at 51.8 mW/cm²
Block Blue Light ULTIMATE XXL
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Measured
$4499.95
≈ 7 min 36 sec / session
at 75 mW/cm²
Block Blue Light PowerPanel MAX
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Brand claim
$1099.95
≈ 6 min 57 sec / session
at 82 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 35181944 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.