🧑 Human 🎲 Randomized trial, sham-controlled 👥 40 participants (34 completed) ⌛ 1-month treatment / 3-month study · 2020 · Iran (Tehran)
Evaluation of the Therapeutic Effect of Low Level Laser in Controlling Low Back Pain: A Randomized Controlled Trial.
Kholoosy · J Lasers Med Sci · 2020
The protocol this study used
What the authors concluded
There was significant improvement in pain (P<0.001 for both groups), functional status (Case group: P <0.001; control group: P=0.004) and spinal ROM (Case group: P <0.001; control group: P =0.007) in both groups at the end of the first month, but these gains persisted for 3 months only in the case group (P <0.001). Regarding spinal tenderness, it was disappeared in 89.47% of the patients in the
Devices that emit this wavelength
Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 1.5 J/cm² at that intensity.
DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.
Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.
Source
Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.