redlight.store

🧑 Human 📄 Single-arm trial 👥 41 participants ⌛ single treatment / 6-month follow-up · 2005 · Poland (Wroclaw)

Endoluminal phototherapy for prevention of restenosis: preliminary results at 6-month follow-up.

Derkacz · Photomed Laser Surg · 2005

The protocol this study used

Wavelength
808 nm
Dose
9 J/cm²
Sessions
—
Per session
—

What the authors concluded

Angiographic follow-up (n = 30) revealed restenosis in 9% and 25% of patients after stent implantation and balloon angioplasty, respectively. The MACE rate was 4.5% and 12.5% in stent and balloon-treated patients, respectively." "Laser phototherapy gives very promising results in restenosis prevention, especially after stent implantation. The treatment method is safe, with a low rate of MACE in

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 9 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 2 min 48 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 1 min 40 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 3 min 2 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 3 min 41 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 2 min 9 sec / session
at 70 mW/cm²
Infraredi Pro Max 2.0
630 · 660 · 810 · 830 · 850 nm
Measured
$959
≈ 2 min 5 sec / session
at 72 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 16356143 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.