redlight.store

🧑 Human 🎲 Randomized trial, double-blind 👥 40 participants ⌛ 2-week treatment -> 4-week follow-up · 2020 · Turkey (Gaziantep)

Efficacy of high intensity laser therapy in knee osteoarthritis: a double-blind controlled randomized study

Akaltun · Clin Rheumatol · 2020

The protocol this study used

Wavelength
1064 nm
Dose
12 J/cm²
Sessions
10
Per session
—

What the authors concluded

No significant differences were detected in the VAS, WOMAC-pain, WOMAC-function, WOMAC-stiffness, and WOMAC-total values of both groups in the comparisons of the two groups at the end of the treatment (in the 2nd week)" "The VAS, WOMAC-pain, WOMAC-function, WOMACstiffness, and WOMAC-total values were significantly lower in the 6th week in HILT + ET group compared to the PL + ET group (p < 0.05)

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 12 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 2 min 13 sec / session
at 90.3 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 2 min 51 sec / session
at 70 mW/cm²
Rouge Pro G4
630 · 650 · 660 · 670 · 810 · 830 · 850 · 1060 nm
Measured
$1,121
≈ 3 min 23 sec / session
at 59.2 mW/cm²
PlatinumLED BIOMAX PRO ULTRA
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,599
≈ 1 min 59 sec / session
at 101 mW/cm²
Block Blue Light ULTIMATE XXL
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Measured
$4499.95
≈ 2 min 40 sec / session
at 75 mW/cm²
Block Blue Light PowerPanel MAX
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Brand claim
$1099.95
≈ 2 min 26 sec / session
at 82 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 33074393 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.