redlight.store

🧑 Human 🎲 Randomized trial, double-blind 👥 34 participants ⌛ 3 weeks · 2026 · Thailand (Khon Kaen)

Efficacy of High-Intensity Laser Therapy Combined With Plantar Fascia Stretching Exercises in the Treatment of Plantar Fasciitis: Randomized, Double-Blind, Sham-Controlled Trial

Jitpimolmard · JMIR Rehabil Assist Technol · 2026

The protocol this study used

Wavelength
1064 nm
Dose
120 J/cm²
Sessions
9
Per session
4 min 10 sec

What the authors concluded

Based on intragroup comparison, both groups demonstrated statistically significant improvements in all outcomes compared with baseline (P<.001). However, no significant differences were found between the 2 groups across all outcomes. The mean difference in pain reduction, measured by the visual analog scale, was -35.3 (95% CI -45.3 to -25.0) mm in the HILT group and -30.4 (95% CI -46.3 to -14.4)

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 120 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 22 min 9 sec / session
at 90.3 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 28 min 34 sec / session
at 70 mW/cm²
Rouge Pro G4
630 · 650 · 660 · 670 · 810 · 830 · 850 · 1060 nm
Measured
$1,121
≈ 33 min 47 sec / session
at 59.2 mW/cm²
PlatinumLED BIOMAX PRO ULTRA
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,599
≈ 19 min 48 sec / session
at 101 mW/cm²
Block Blue Light ULTIMATE XXL
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Measured
$4499.95
≈ 26 min 40 sec / session
at 75 mW/cm²
Block Blue Light PowerPanel MAX
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Brand claim
$1099.95
≈ 24 min 23 sec / session
at 82 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 41719484 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.