redlight.store

🧑 Human 🎲 Randomized trial, double-blind, crossover 👥 11 participants ⌛ 3 sessions with 48h washout intervals · 2023 · Brazil (Londrina)

Effects of Photobiomodulation on High-Intensity Intermittent Anaerobic Performance of Lower Limbs in Brazilian Jiu-Jitsu Athletes: A Randomized, Crossover, Double-Blind Clinical Trial

Santos Junior · Int J Exerc Sci · 2023

The protocol this study used

Wavelength
630 nm
Dose
4.5 J/cm²
Sessions
1
Per session
—

What the authors concluded

No differences were observed between treatments in SJ height, Wingate performance, HR, and RPE (p>0.05; for all comparisons). The Wingate test session promoted a reduction in anaerobic capacity in the second and third sets in all conditions, indicating fatigue (p<0.05)." "Treatment with PBM did not produce a dose-dependent ergogenic response in high-intensity intermittent performance in BJJ athl

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 4.5 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 59 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 84 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 50 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 1 min 31 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 1 min 51 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 64 sec / session
at 70 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 38288386 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.