redlight.store

🧑 Human (rugby athletes) 🎲 Randomized trial, crossover 👥 18 participants ⌛ 4 phases (control, pre-exercise PBM, PBM during exercise and post-exercise PBM) · 2024 · Brazil (Londrina)

Effects of photobiomodulation applied at different times on functional performance and ergogenic response of rugby athletes: Randomized clinical trial

da Costa Santos · J Bodyw Mov Ther · 2024

The protocol this study used

Wavelength
850 nm
Dose
8 J/cm²
Sessions
—
Per session
—

What the authors concluded

No differences were found between groups in CK, lactate, and performance in the functional tests between groups and times. Only the PBpre presented improved performance in the first Yoyo-1R1 test (p < 0.01), while the PBint improved in the second Yoyo-IR1 test and BST (p < 0.05)." "The PBM did not change muscle damage markers or performance in the functional tests. For an ergogenic response, pho

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 8 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 1 min 45 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 2 min 30 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 89 sec / session
at 90.3 mW/cm²
HoogaHealth PRO1500
660 · 850 nm
Measured
$1,199
≈ 1 min 33 sec / session
at 86 mW/cm²
Joovv Solo 3.0
660 · 850 nm
Measured
$1,499
≈ 2 min 15 sec / session
at 59.2 mW/cm²
LUMEBOX 2.0
660 · 850 nm
Measured
$629
≈ 64 sec / session
at 125 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 38763575 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.