🧑 Human 🎲 Randomized trial, sham-controlled 👥 60 participants ⌛ 4-week treatment / 6-week study (?) · 2022 · Brazil (Londrina)

Effects of photobiomodulation and deep water running in patients with chronic non-specific low back pain: a randomized controlled trial

Nardin · Lasers Med Sci · 2022

The protocol this study used

Wavelength
660, 850 nm
Dose
1.5 J/cm²
Sessions
8
Per session
2 min

What the authors concluded

In the intragroup comparisons, there were statistically significant changes in the TGPBM and GPBM groups in the outcomes pain intensity, disability (reductions in both groups), and in cortisol (increased in the TGPBM and reduced in the GPBM); in the TGPLA group, there was a statistically significant reduction only in the outcome of pain intensity. In the intergroup comparison, in the comparison

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 1.5 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 20 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 28 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 17 sec / session
at 90.3 mW/cm²
HoogaHealth PRO1500
660 · 850 nm
Measured
$1,199
≈ 17 sec / session
at 86 mW/cm²
Joovv Solo 3.0
660 · 850 nm
Measured
$1,499
≈ 25 sec / session
at 59.2 mW/cm²
LUMEBOX 2.0
660 · 850 nm
Measured
$629
≈ 12 sec / session
at 125 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 35246766 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.