🧑 Human 📄 Case series 👥 13 cases · 2016 · Iran (Tehran)
Effects of low level laser therapy on the prognosis of split-thickness skin graft in type 3 burn of diabetic patients: a case series.
Dahmardehei · Lasers Med Sci · 2016
The protocol this study used
What the authors concluded
The results of this study showed complete healing in the last 8 weeks for all patients who were candidates for amputation. In this case series, we present 13 cases of diabetic ulcer with type 3 burn wound, candidate for amputation, who healed completely using LLLT and STSG. This is the first time that these two techniques are combined for treatment of burn ulcer in diabetic patients. Using LLLT w
Devices that emit this wavelength
Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 2 J/cm² at that intensity.
DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.
Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.
Source
Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.