redlight.store

🐀 Rat · 2025 · Brazil (Itaperuna)

Effects of Chronic Photobiomodulation with Transcranial Near-Infrared Laser on Seizure Frequency and Brain Metabolomics of Rats with Pilocarpine-Induced Seizures

Cardoso · Mol Neurobiol · 2025

The protocol this study used

Wavelength
810 nm
Dose
535.7 J/cm²
Sessions
30
Per session
30 sec

What the authors concluded

Our data show that PBM treatment significantly reduced the seizure frequency in rats with pilocarpine-induced seizures. Additionally, significant changes were observed in the metabolomic profiles of the neocortex and hippocampus. In the neocortex, the treatment reduced metabolic pathways associated with excitotoxicity and oxidative stress. In the hippocampus, an increase in phenylalanine concentr

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 535.7 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 166 min 53 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 98 min 52 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 180 min 44 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 219 min 22 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 127 min 33 sec / session
at 70 mW/cm²
Infraredi Pro Max 2.0
630 · 660 · 810 · 830 · 850 nm
Measured
$959
≈ 124 min / session
at 72 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 40658337 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.