🧑 Human 🎲 Randomized trial 👥 60 participants ⌛ ~7 weeks · 2024 · Iran (Tehran)

Effect of Visible and Infrared Photobiomodulation on Diabetic Foot Ulcers

Tabeie · J Lasers Med Sci · 2024

The protocol this study used

Wavelength
630, 810 nm
Dose
64.17 J/cm²
Sessions
20
Per session
30 min

What the authors concluded

The mean area of ulcers in the LLLT group reduced significantly (P<0.001) from 441.7±365.5 mm2 before LLLT to 163.9±213.9 mm2 from the baseline up to the last session of LLLT, indicating a 62.99% reduction in mean ulcer area. In the control group, the mean ulcer area did not change significantly. Wagner's classification of the patients in the LLLT group reduced to lower grades significantly (

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 64.17 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 13 min 59 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 19 min 59 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 11 min 51 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 21 min 39 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 26 min 17 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 15 min 17 sec / session
at 70 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 39050995 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.