🧑 Human 🎲 Randomized trial 👥 40 participants ⌛ 1 month · 2023 · Egypt (Cairo)

Effect of low-level laser therapy on quadriceps and foot muscle fatigue in children with spastic diplegia: a randomized controlled study

Abdelhalim · Lasers Med Sci · 2023

The protocol this study used

Wavelength
810 nm
Dose
164.85 J/cm²
Sessions
5
Per session
60 sec

What the authors concluded

This study was the first to show the effect of LLLT on power gains on quadriceps and dorsiflexors in children with CP diplegia." Comment: The 30 J dose per point does not seem likely as the power output is 0.2 W and the irradiation time is 30 seconds per point, thus the dose should be 6 J per point. Comment: Despite positive conclusions, the actual data doesn't seem to show as clear benefits be

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 164.85 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 51 min 21 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 30 min 26 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 55 min 37 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 67 min 30 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 39 min 15 sec / session
at 70 mW/cm²
Infraredi Pro Max 2.0
630 · 660 · 810 · 830 · 850 nm
Measured
$959
≈ 38 min 10 sec / session
at 72 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 37572215 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.