🧑 Human 📄 Non-randomized study, self-controlled, double-blind 👥 16 participants ⌛ single session · 2013 · Germany (Erlangen)

Effect of low-level laser therapy on blood flow and oxygen- hemoglobin saturation of the foot skin in healthy subjects: a pilot study.

Heu · Laser Ther · 2013

The protocol this study used

Wavelength
660 nm
Dose
5.73 J/cm²
Sessions
1
Per session
15 min

What the authors concluded

No evidence that the LLLT has a significant instant effect on the circulation or the oxygen saturation could be found." "No immediate effect of an LLLT on the perfusion or oxygenation situation is to be expected with physiologically normal starting conditions. An additional investigation should be carried out in which either the radiation dose is varied or the starting conditions are pathologica

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 5.73 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 75 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 1 min 47 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 63 sec / session
at 90.3 mW/cm²
HoogaHealth PRO1500
660 · 850 nm
Measured
$1,199
≈ 67 sec / session
at 86 mW/cm²
Joovv Solo 3.0
660 · 850 nm
Measured
$1,499
≈ 1 min 37 sec / session
at 59.2 mW/cm²
LUMEBOX 2.0
660 · 850 nm
Measured
$629
≈ 46 sec / session
at 125 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 24155546 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.