redlight.store

🐀 Rat · 2019 · Brazil (Sāo Paulo)

Effect of low-level laser therapy and zoledronic acid on bone repair process

Buchignani · Lasers Med Sci · 2019

The protocol this study used

Wavelength
808 nm
Dose
57.14 J/cm²
Sessions
—
Per session
2 min 13 sec

What the authors concluded

In intergroup comparison, group 1 (mean ± SD= 45.2 ± 18.56%) showed a lower bone formation compared with groups 2 (64.13 ± 3.51%) (p = 0.358) and 4 (15.2 ± 78.22%) (p = 0.049), at the 14-day period. Group 3 (20.99 ± 7.42%) also presented a lower amount of neoformed bone tissue, with statistically significant difference when compared with groups 1 (p = 0.002), 2, and 4 (p ≤ 0,001). After 28 days,

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 57.14 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 17 min 48 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 10 min 33 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 19 min 17 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 23 min 24 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 13 min 36 sec / session
at 70 mW/cm²
Infraredi Pro Max 2.0
630 · 660 · 810 · 830 · 850 nm
Measured
$959
≈ 13 min 14 sec / session
at 72 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 39016360 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.