🐀 Rat · 2018 · Brazil (Campina Grande)

Effect of blue LED on the healing process of third-degree skin burns: clinical and histological evaluation.

de Alencar Fernandes Neto · Lasers Med Sci · 2018

The protocol this study used

Wavelength
470 nm
Dose
12.5 J/cm²
Sessions
—
Per session
28 sec

What the authors concluded

It was observed that there were no statistically significant differences in the Wound Retention Index (WRI) of the BLUE group in relation to CTR group (p > 0.05) at the evaluation times. After 14, 21, and 28 days, it was observed that the animals in the BLUE group consumed more feed than animals in the CTR group (p < 0.05). At 7 days, there was a statistically significant increase in the angiog

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 12.5 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 2 min 18 sec / session
at 90.3 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 2 min 59 sec / session
at 70 mW/cm²
PlatinumLED BIOMAX PRO ULTRA
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,599
≈ 2 min 4 sec / session
at 101 mW/cm²
PlatinumLED SaunaMAX Pro
480 · 630 · 660 · 810 · 830 · 850 nm
Measured
$959
≈ 5 min 4 sec / session
at 41.1 mW/cm²
PlatinumLED BIOMAX 600
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Brand claim
$1,049
≈ 1 min 37 sec / session
at 129 mW/cm²
Hooga Red Light Therapy Facial Wand
415 · 460 · 630 nm
Not published
$70
no irradiance published

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 30276489 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.