redlight.store

🧑 Human 🎲 Randomized trial 👥 59 participants ⌛ 3 weeks · 2021 · China (Suzhou)

Clinical effects of high-intensity laser therapy on patients with chronic refractory wounds: a randomised controlled trial

Lu · BMJ Open · 2021

The protocol this study used

Wavelength
1064 nm
Dose
80 J/cm²
Sessions
9
Per session
—

What the authors concluded

The BWAT scores significantly decreased in the treatment group compared with the control group at the end of 3-week treatment (difference=-3.6; 95% CI -6.3 to-0.8; p<0.01). Similarly, patients in treatment group showed a significant reduction of PUSH scores compared with the control group (difference=-5.3; 95% CI -8.1 to -2.6; p<0.01)." "The therapeutic effects of HILT on chronic refractory woun

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 80 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 14 min 46 sec / session
at 90.3 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 19 min 3 sec / session
at 70 mW/cm²
Rouge Pro G4
630 · 650 · 660 · 670 · 810 · 830 · 850 · 1060 nm
Measured
$1,121
≈ 22 min 31 sec / session
at 59.2 mW/cm²
PlatinumLED BIOMAX PRO ULTRA
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,599
≈ 13 min 12 sec / session
at 101 mW/cm²
Block Blue Light ULTIMATE XXL
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Measured
$4499.95
≈ 17 min 47 sec / session
at 75 mW/cm²
Block Blue Light PowerPanel MAX
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Brand claim
$1099.95
≈ 16 min 16 sec / session
at 82 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 34253665 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.