Study 1 (skin rejuvenation) 🧑 Human 📄 Single-arm trial 👥 20 participants ⌛ 12 weeks Study 2 (hair growth) 🧑 Human 📄 Single-arm trial 👥 25 participants ⌛ 20 weeks · 2025 · Korea (Seoul)

Clinical Application of a New Near-Infrared Light-Emitting Diode with Broader Spectrum for Skin Rejuvenation and Hair Growth Enhancement

Kim · Aesthet Plast Surg · 2025

The protocol this study used

Wavelength
600, 1000 nm
Dose
1.45 J/cm²
Sessions
60
Per session
30 min

What the authors concluded

Skin rejuvenation showed significant improvements, with wrinkles decreasing by up to 27.22% and skin texture, elasticity, moisture, and density also improving. Hair growth evaluation indicated a 1.33% increase in hair count by 20 weeks, with high participant satisfaction and no adverse reactions reported." Comment: The energy densities (fluence) were calculated based on the reported total dose

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 1.45 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 27 sec / session
at 53.5 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 29 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 36 sec / session
at 40.7 mW/cm²
MitoPRO 300X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$449
≈ 28 sec / session
at 51.8 mW/cm²
Block Blue Light ULTIMATE XXL
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Measured
$4499.95
≈ 19 sec / session
at 75 mW/cm²
Block Blue Light PowerPanel MAX
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Brand claim
$1099.95
≈ 18 sec / session
at 82 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 41559389 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.