redlight.store

🧑 Human 📄 Non-randomized study, controlled 👥 53 participants ⌛ · 2025 · Brazil (Santa Maria)

Blue LED photobiomodulation in the prevention of radiodermatitis in breast cancer survivors: a clinical trial

Pivetta · Support Care Cancer · 2025

The protocol this study used

Wavelength
470 nm
Dose
18.6 J/cm²
Sessions
—
Per session
—

What the authors concluded

The RD occurrence was 28% lower (p = 0.039) in the intervention group (n = 11) compared to the CG (n = 19). Dermatological quality of life presents a moderate reduction over time only in the patients in the CG (p = 0.005). This worsening is attributed to increases in the DLQI scores for symptoms and feelings (p = 0.003), daily activities (p = 0.003), and treatment (p = 0.005).

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 18.6 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 3 min 26 sec / session
at 90.3 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 4 min 26 sec / session
at 70 mW/cm²
PlatinumLED BIOMAX PRO ULTRA
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,599
≈ 3 min 4 sec / session
at 101 mW/cm²
PlatinumLED SaunaMAX Pro
480 · 630 · 660 · 810 · 830 · 850 nm
Measured
$959
≈ 7 min 33 sec / session
at 41.1 mW/cm²
PlatinumLED BIOMAX 600
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Brand claim
$1,049
≈ 2 min 24 sec / session
at 129 mW/cm²
Hooga Red Light Therapy Facial Wand
415 · 460 · 630 nm
Not published
$70
no irradiance published

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 41454020 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.