redlight.store

🧪 In vitro · 2021 · China (Beijing)

Antifibrotic effects of Hypocrellin A combined with LED red light irradiation on keloid fibroblasts by counteracting the TGF-β/Smad/autophagy/apoptosis signalling pathway

Niu · Photodiagnosis Photodyn Ther · 2021

The protocol this study used

Wavelength
630 nm
Dose
3 J/cm²
Sessions
—
Per session
—

What the authors concluded

Hypocrellin A (HA) was shown to have excellent light induced anticancer, antimicrobial and antiviral activities. In this experiment, we investigated the impacts of HA united light-emitting diode (LED) red light irradiation on human keloid fibroblast cells (KFs). Our results showed that HA combined with red light irradiation treatment (HA-R-PDT) decreased KF viability, reduced KF collagen product

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 3 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 39 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 56 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 33 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 61 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 74 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 43 sec / session
at 70 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 33556618 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.