Acute Photobiomodulation Effects Through a Cluster Device on Skeletal Muscle Fatigue of Biceps Brachii in Young and Healthy Males: A Randomized Double-Blind Session

Vassão · Photobiomodul Photomed Laser Surg · 2020

The protocol this study used

Wavelength
630, 850 nm
Dose
91 J/cm²
Sessions
1
Per session
40 sec

What the authors concluded

There was no difference between red and infrared PBM in reduction of biceps brachii fatigue. However, the EMGFI delta value was greater in the IPG compared with the CG, suggesting that infrared can be more effective in reducing biceps brachii fatigue." Comment: The 100mW/diode * 14 diodes * 40 seconds equals 56J. This does not match the claimed 24 joules.

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 91 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500+
630 · 660 · 830 · 850 nm
Measured
$1,169
≈ 19 min 50 sec / session
at 76.5 mW/cm²
MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 28 min 21 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 16 min 48 sec / session
at 90.3 mW/cm²
HoogaHealth PRO1500
660 · 850 nm
Measured
$1,199
≈ 17 min 38 sec / session
at 86 mW/cm²
Joovv Solo 3.0
660 · 850 nm
Measured
$1,499
≈ 25 min 37 sec / session
at 59.2 mW/cm²
LUMEBOX 2.0
660 · 850 nm
Measured
$629
≈ 12 min 8 sec / session
at 125 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.