🧑 Human 🎲 Randomized trial, sham-controlled 👥 20 participants ⌛ 6-week treatment / 7-week study · 2026 · Canada (Toronto)

A multimodal evaluation of transcranial photobiomodulation in mild cognitive impairment: Cognitive, metabolic, and neuroimaging outcomes of a pilot randomized controlled trial

Rashidi-Ranjbar · J Alzheimers Dis · 2026

The protocol this study used

Wavelength
810 nm
Dose
45 J/cm²
Sessions
36
Per session
20 min

What the authors concluded

Adverse events (AEs) were reported by 10 of 20 participants (4 active, 6 sham)." "Compared with sham, active tPBM produced greater improvement in global cognition (Mini-Mental State Examination; p = 0.03, d = 1.05) and episodic memory (California Verbal Learning Test-II long-delay recognition; p = 0.02, d = 1.09). Serum pyruvate and lactate increased with a reduced lactate-to-pyruvate (L/P) rati

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 45 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 14 min 1 sec / session
at 53.5 mW/cm²
PlatinumLED BIOMAX 900
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$1,299
≈ 8 min 18 sec / session
at 90.3 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 15 min 11 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 18 min 26 sec / session
at 40.7 mW/cm²
PlatinumLED BIOMAX 300
480 · 630 · 660 · 810 · 830 · 850 · 1060 nm
Measured
$659
≈ 10 min 43 sec / session
at 70 mW/cm²
Infraredi Pro Max 2.0
630 · 660 · 810 · 830 · 850 nm
Measured
$959
≈ 10 min 25 sec / session
at 72 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 42231857 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.