redlight.store

🧑 Human 📄 Single-arm trial 👥 10 participants ⌛ 8-week treatment -> 3-month follow-up + 🧪 In vitro · 2022 · China (Shanghai)

590 nm LED Irradiation Improved Erythema through Inhibiting Angiogenesis of Human Microvascular Endothelial Cells and Ameliorated Pigmentation in Melasma

Dai · Cells · 2022

The protocol this study used

Wavelength
590 nm
Dose
20 J/cm²
Sessions
8
Per session
16 min 40 sec

What the authors concluded

We previously demonstrated the yellow light of light-emitting diodes (LED) could inhibit melanogenesis through the photobiomodulation (PBM) of melanocytes and keratinocytes. In the current study, we investigated the effect of 590 nm LED on the function of human microvascular endothelial cells (HMEC-1). We revealed 0-40 J/cm2 590 nm LED had no toxic effect on HMEC-1 in vitro. 590 nm LED irradiat

Devices that emit this wavelength

Matched on wavelength within 15nm, since LED bins vary by roughly that much and a tighter match would be false precision. Where we have an irradiance figure, the session length is the time needed to reach this study's dose of 20 J/cm² at that intensity.

DISCLOSURE — we earn commission on purchases made through our links, at no extra cost to you. Rankings come from specifications and measurements, never from commission rates.

MitoPRO 1500X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$1,299
≈ 6 min 14 sec / session
at 53.5 mW/cm²
MitoADAPT MAX 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$1,499
≈ 6 min 45 sec / session
at 49.4 mW/cm²
MitoADAPT MIN 4.0
590 · 630 · 660 · 670 · 810 · 830 · 850 · 940 nm
Measured
$549
≈ 8 min 11 sec / session
at 40.7 mW/cm²
MitoPRO 300X
590 · 630 · 660 · 810 · 830 · 850 nm
Measured
$449
≈ 6 min 26 sec / session
at 51.8 mW/cm²
Block Blue Light ULTIMATE XXL
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Measured
$4499.95
≈ 4 min 27 sec / session
at 75 mW/cm²
Block Blue Light PowerPanel MAX
590 · 630 · 650 · 810 · 830 · 850 · 1060 nm
Brand claim
$1099.95
≈ 4 min 4 sec / session
at 82 mW/cm²

Matching a wavelength is not the same as reproducing a trial. Session times assume the device's published irradiance is accurate at the distance it was measured, which on brand-claim figures is often optimistic. Where a device publishes both a peak and an average we use the average, and where it publishes a falloff curve we use the lowest figure, so these times run long rather than short. Clinical protocols also control for spot size, contact and skin type in ways a home device cannot.

Source

PubMed 36552713 →

Dosimetry extracted by Vladimir Heiskanen in Photobiomodulation (PBM) research - a comprehensive database. Citation resolved against PubMed.